AOSIF 250kva diesel generator power by Cummins diesel engine
Basic Info
Model No.: AC275
Product Description
Genset | Prime power (KVA) | Standby power (kw) | Engine model | Fuel | Open Genset |
AC150 | 120/150 | 108/135 | 6BTAA5.9-G2 | 27 | 2210x785x1394 |
AC165-I | 150/165 | 120/132 | 6CTA8.3-G2 | 40 | 2257x790x1497 |
AC206 | 188/206 | 150/165 | 6CTA8.3-G2 | 40 | 2372x790x1507 |
AC220-I | 200/220 | 160/176 | 6CTAA8.3-G2 | 40 | 2463x945x1606 |
Genset | Prime power (KVA) | Standby power (kw) | Engine model | Fuel | Open Genset |
AC275-I | 250/275 | 200/220 | 6LTAA8.9-G2 | 53 | 2540x950x1608 |
AC344-I | 313/343 | 250/275 | QSM11-G2 | 66 | 2920x1000x1703 |
AC500 | 450/500 | 360/400 | QSZ13-G2 | 70.4 | 2950x1360x1855 |
AC550 | 500/550 | 400/440 | QSZ13-G3 | 101 | 3150x1360x1855 |
Generator set included: Diesel Engine, Brushless Alternator, Radiator, self-starting control panel, circuit breaker panel, Vibration damping pads, Hi-strength base frame . accessories Included: industrial type silencer, flexible bellow, Elbow and Flanges, Starting Battery & battery charger, Battery switch with cables Documents included: manual book, product qualified card Optional supply scope: 1.ATS 2. Synchronization System 3. External daily fuel tank 4. Silent Canopy 5. Trailer 6. Auto Fuel Pump 7. Fuel and Water Separator 8. Lub Oil Heater 9. Coolant Heater 10. Fuel Drain Pump Packaging & Shipping Packaging & Shipping foam and PE film package, plywood package,
plastic film package Our Services Our warranty: One year or 1000hours whichever comes first Company Information Xiamen AOSIF Engineering LTD
Establish year: 2001.
Main product: Diesel Generator Set, Gas Generator.
OEM brand: Cummins(DCEC,CCEC),India Cummins, UK Cummins. UK Perkins,
Korean Doosan,Deutz and Other brand. FAQ
Fault Type:Diesel engine can not start | |
Fault Description and Reason | Remedy |
Fuel system failure: The diesel engine doesn’t ignite when rotated by the electric motor. | |
Return pipe has no fuel return. | |
Air in the fuel system. | Check whether the fuel pipe joints are loosened; vent the air in the fuel. Unfasten the vent screw on the fuel injection pump and fuel filter; pump the fuel with the hand pump, until there is no air bubbles in the overflowing fuel; ighten the vent screw, continue pumping; when fuel flows into the return pipe, tighten the hand pump. |
Fuel pipe clogged | Check and ensure that the fuel pipes are not clogged. |
Fuel filter Clogged | Clean the filter or replace the filter insert |
Fuel pump doesn’t work or fails while working. | Check the fuel pump and the fuel intake pipe |
Insufficient fuel injection, failed injection or fuel not atomized | Replace injector assembly |
Injection pump speed governing lever placed in wrong position. | When starting the engine, place the lever in such |
a position that the engine rotates at 600-800 r/min at no-load. | |
Electric starting system failure | |
Misconnection of electric wires or inadequate grounding | Check that the electric wires are firmly and reliably connected. |
Insufficient battery capacity | Replace with a well-charged battery or use batteries in parallel. |
Fuel pump rod rack choked | Open the peep hole on the pressure fuel pump and move the acting rack to see whether there is any obstruction. For pressure fuel pump equipped with electronic speed governor, if no rod rack gets choked, jump out Terminal 1# and 6# on the control panel. Meanwhile the speed actuator shall be in the “maximum fuel” position and click sounds shall be easily audible. This will help staff decide whether there is fault with the electronic speed governor control panel. |
Electronic speed governor failure | Please follow the testing procedures specified in the handbook for the electronic speed governor(actuator, control panel, speed sensor) and find out the reason. |










Product Categories : Power By Cummins Engine > 50HZ Power By Cummins Engine