150kw 188kVA Genuine Cummins Marine Genset

Basic Info

Model No.:  CCFJ-100J-Z

Product Description

Model NO.: CCFJ-100J-Z Installation Method: Fixed Cooling Method: Water Cooling Speed: 1500prm 50Hz Usage: Common Units Excitation Mode: Self-Excited Delivery Time: 20days After 30% Deposit Voltage Standard: 50Hz or 60Hz Specification: CE, SGS, SONCAP, ETC HS Code: 8502120000 Type: Micro-Computer Control Automatic diesel generator Stroke: Four Stroke Output Type: AC Three Phase Conditions of Use: Land Use Landuse Type of Unit: Automation Type Warranty: 1 Year Or1000 Hours Payment Term: 30% Deposit, 70% Paid Before Shipping Trademark: UNITE POWER Origin: China
Cummins Marine Generator set 




Product Manufacture Standards
1.The complete gensets design, production and service accord with ISO9001standard.
2.The product performance accords with GB2820 and GB12786 standard (same as ISO8528).
Certificates:
BV and CCS marine class society, ISO9001-2000 ABS, BV and CCS etc.
4 Sets of Advanced Product Test Equipments from UK
1.PT Pump 2.inspection and test for injector 3.Gearbox
4.Water and electricity power test equipment for generator. It is able to test four gensets (each under 1000KW) at the same time.
a.Marine classification society certificate
b.Genset including public foundation
c.Appurtenance and tools delivered by subconstractors
d.Spare parts of the gensets (according the ordering protocol signed by parties)
e.Genset quality certificate
f.Genset/Diesel Engine/Generator/Turbocharger operation and maintenance instruction
g.Genset/diesel engine/Generator outline and installation drawings
h.Generator excitation system dragram
i.Genset operation and maintenance records
j.Genset attached tools list
k.Package list
l.Spare parts list 
Cummins main marine diesel genset(60HZ 1800RPM)
Cummins main marine diesel genset(60HZ 1800RPM)
Genset Rated Power Standby Power FC Engine Alternator Dimension G.W
Model kw kva kw kva (g/kw.h) Model No.of cylinder(mm) Bore*stroke(mm) Displacement(L) Stamford LxWxH(mm) kg
CCFJ40J-Z 50 63 55 69 211 4BTA3.9-GM65 4L 102*120 3.9 UCM224E 1760x710x1160 1110
CCFJ80J-Z 80 100 88 110 212 6BT5.9-GM100 6L 102*120 5.9 UCM274C 1870x800x1300 1190
CCFJ100J-Z 100 125 110 138 212 6BTA5.9-GM120 6L 102*120 5.9 UCM274D 1870x800x1300 1270
CCFJ110J-Z 110 138 121 151 212 6CT8.3-GM129 6L 114*135 8.3 UCM274E 2150x900x1400 2000
CCFJ150J-Z 150 188 165 206 209 6CTA8.3-GM175 6L 114*135 8.3 UCM274F 2150x900x1400 2000
CCFJ250J 250 313 275 344 220 NTA855-DM 6L 140*152 14 HCM434D 2910x955x1700 3800
CCFJ308J 308 385 339 424 220 NTA855-DM 6L 140*152 14 HCM434E 2910x955x1700 4000
CCFJ418J 418 523 460 575 204 K19-DM 6L 159*159 19 HCM534C 3190x920x1890 4250
CCFJ495J 495 619 545 681 203 K19-DM 6L 159*159 19 HCM534D 3190x920x1890 4290
CCFJ517J 517 646 569 711 313 K19-DM 6L 159*159 19 HCM534D 4100x1230x2330 7000
CCFJ925J 925 1156 1018 1272 214 KTA38-DM1 12V 159*159 38 LVM634D 4100x1230x2330 7250
CCFJ990J 990 1238 1089 1361 213 KTA38-DM1 12V 159*159 38 LVM634F 4100x1230x2330 7300
Cummins main marine diesel genset(50HZ 1500RPM).
Genset Rated Power Standby Power FC Engine Alternator Dimension G.W
Model kw kva kw kva (g/kw.h) Model No.of cylinder Bore*stroke(mm) Displacement(L) Stamford LxWxH(mm) kg
CCFJ40J-Z 40 50 44 55 211 4BTA3.9-GM47 4L 102*120 3.9 UCM224E 1760x710x1160 1110
CCFJ50J-Z 50 63 55 69 210 6BT5.9-GM83 6L 102*120 5.9 UCM224F 1870x800x1300 1190
CCFJ64J-Z 64 80 70 88 210 6BT5.9-GM83 6L 102*120 5.9 UCM274C 1870x800x1300 1270
CCFJ75J-Z 75 94 83 103 210 6BT5.9-GM83 6L 102*120 5.9 UCM274C 1870x800x1300 1500
CCFJ90J-Z 90 113 99 124 212 6BTA5.9-GM100 6L 102*120 5.9 UCM274D 1870x800x1300 2000
CCFJ100J-Z 100 125 110 138 209 6CT8.3-GM115 6L 114*135 8.3 UCM274E 2150x900x1400 2050
CCFJ120J-Z 120 150 132 165 209 6CTA8.3-GM155 6L 114*135 8.3 UCM274G 2150x900x1400 2060
CCFJ140J-Z 140 175 154 193 209 6CTA8.3-GM155 6L 114*135 8.3 UCM274H 2150x900x1400 2070
CCFJ200J 200 250 220 275 219 NTA855-DM 6L 140*152 14 HCM434D 2910X956X1700 3680
CCFJ250J 250 313 275 344 219 NTA855-DM 6L 140*152 14 HCM434E 2910X956X1700 3800
CCFJ280J 280 350 308 385 219 NTA855-DM 6L 140*152 14 HCM434F 2910X956X1700 4000
CCFJ300J 300 375 330 413 209 K19-DM 6L 159*159 19 HCM534C 3190x920x1890 4000
CCFJ350J 350 438 385 481 204 K19-DM 6L 159*159 19 HCM534D 3190x920x1890 4100
CCFJ400J 400 500 440 550 203 KTA19-DM 6L 159*159 19 HCM534E 3190x920x1890 4250
CCFJ680J 680 850 748 935 213 KTA38-DM1 12V 159*159 38 LVM634E 4100x1230x2330 6100
CCFJ800J 800 1000 880 1100 213 KTA38-DM1 12V 159*159 38 LVM634F 4100x1230x2330 7200
Note: FC: fuel consumption; 50HZ standard voltage is 220v/380v;60HZ Standard voltage is 127v/220v, Other type voltage also can be adjustable.
Genset Rated Power Standby Power FC Engine Alternator Dimension G.W Model kw kva kw kva (g/kw.h) Model No.of cylinder(mm) Bore*stroke(mm) Displacement(L) Stamford LxWxH(mm) kg CCFJ40J-Z 50 63 55 69 211 4BTA3.9-GM65 4L 102*120 3.9 UCM224E 1760x710x1160 1110 CCFJ80J-Z 80 100 88 110 212 6BT5.9-GM100 6L 102*120 5.9 UCM274C 1870x800x1300 1190 CCFJ100J-Z 100 125 110 138 212 6BTA5.9-GM120 6L 102*120 5.9 UCM274D 1870x800x1300 1270 CCFJ110J-Z 110 138 121 151 212 6CT8.3-GM129 6L 114*135 8.3 UCM274E 2150x900x1400 2000 CCFJ150J-Z 150 188 165 206 209 6CTA8.3-GM175 6L 114*135 8.3 UCM274F 2150x900x1400 2000 CCFJ250J 250 313 275 344 220 NTA855-DM 6L 140*152 14 HCM434D 2910x955x1700 3800 CCFJ308J 308 385 339 424 220 NTA855-DM 6L 140*152 14 HCM434E 2910x955x1700 4000 CCFJ418J 418 523 460 575 204 K19-DM 6L 159*159 19 HCM534C 3190x920x1890 4250 CCFJ495J 495 619 545 681 203 K19-DM 6L 159*159 19 HCM534D 3190x920x1890 4290 CCFJ517J 517 646 569 711 313 K19-DM 6L 159*159 19 HCM534D 4100x1230x2330 7000 CCFJ925J 925 1156 1018 1272 214 KTA38-DM1 12V 159*159 38 LVM634D 4100x1230x2330 7250 CCFJ990J 990 1238 1089 1361 213 KTA38-DM1 12V 159*159 38 LVM634F 4100x1230x2330 7300 Cummins main marine diesel genset(50HZ 1500RPM). Genset Rated Power Standby Power FC Engine Alternator Dimension G.W Model kw kva kw kva (g/kw.h) Model No.of cylinder Bore*stroke(mm) Displacement(L) Stamford LxWxH(mm) kg CCFJ40J-Z 40 50 44 55 211 4BTA3.9-GM47 4L 102*120 3.9 UCM224E 1760x710x1160 1110 CCFJ50J-Z 50 63 55 69 210 6BT5.9-GM83 6L 102*120 5.9 UCM224F 1870x800x1300 1190 CCFJ64J-Z 64 80 70 88 210 6BT5.9-GM83 6L 102*120 5.9 UCM274C 1870x800x1300 1270 CCFJ75J-Z 75 94 83 103 210 6BT5.9-GM83 6L 102*120 5.9 UCM274C 1870x800x1300 1500 CCFJ90J-Z 90 113 99 124 212 6BTA5.9-GM100 6L 102*120 5.9 UCM274D 1870x800x1300 2000 CCFJ100J-Z 100 125 110 138 209 6CT8.3-GM115 6L 114*135 8.3 UCM274E 2150x900x1400 2050 CCFJ120J-Z 120 150 132 165 209 6CTA8.3-GM155 6L 114*135 8.3 UCM274G 2150x900x1400 2060 CCFJ140J-Z 140 175 154 193 209 6CTA8.3-GM155 6L 114*135 8.3 UCM274H 2150x900x1400 2070 CCFJ200J 200 250 220 275 219 NTA855-DM 6L 140*152 14 HCM434D 2910X956X1700 3680 CCFJ250J 250 313 275 344 219 NTA855-DM 6L 140*152 14 HCM434E 2910X956X1700 3800 CCFJ280J 280 350 308 385 219 NTA855-DM 6L 140*152 14 HCM434F 2910X956X1700 4000 CCFJ300J 300 375 330 413 209 K19-DM 6L 159*159 19 HCM534C 3190x920x1890 4000 CCFJ350J 350 438 385 481 204 K19-DM 6L 159*159 19 HCM534D 3190x920x1890 4100 CCFJ400J 400 500 440 550 203 KTA19-DM 6L 159*159 19 HCM534E 3190x920x1890 4250 CCFJ680J 680 850 748 935 213 KTA38-DM1 12V 159*159 38 LVM634E 4100x1230x2330 6100 CCFJ800J 800 1000 880 1100 213 KTA38-DM1 12V 159*159 38 LVM634F 4100x1230x2330 7200 Note: FC: fuel consumption; 50HZ standard voltage is 220v/380v;60HZ Standard voltage is 127v/220v, other type voltage also can be adjustable.
 

Contact us if you need more details on Marine Generator. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Diesel Generator SetElectric Generator. If these products fail to match your need, please contact us and we would like to provide relevant information.

Product Categories : Marine diesel generator set